dc.identifier.citationZamora -Cercado, Jh. F.(2022).Análisis y determinación del agua no facturada por la EPS Moyobamba en el sistema de abastecimiento de agua potable. Tesis para optar el grado de Ingeniero Sanitario. Facultad de Ecología, Universidad Nacional de San Martín, Tarapoto, Perú.es_PE
dc.identifier.urihttp://hdl.handle.net/11458/5999-
dc.description.abstractLa presente investigación tuvo por objetivo determinar el porcentaje de agua no facturada en el sistema de abastecimiento de agua potable de la ciudad de Moyobamba; asimismo, identificar las fuentes de abastecimiento de agua potable de la ciudad de Moyobamba, determinar el balance hídrico y los volúmenes de agua que ingresan al sistema de la EPS Moyobamba, determinar el volumen de agua facturada y determinar las pérdidas de agua en el sistema de abastecimiento de agua potable de la ciudad de Moyobamba. En este sentido, luego de la toma de datos y su procesamiento se concluyó que el ingreso de agua al sistema fue de 3732964 m3 aproximadamente, conformado por el subsistema San Mateo que abastece aproximadamente a 10000 conexiones domiciliarias de las cuales el 90% tienen medidores activos y el 10% no tienen medidor; Almendra que abastece aproximadamente a 1000 conexiones domiciliarias de las cuales el 70% tienen medidores activos y el 30% no tienen medidor y Juninguillo que abastece aproximadamente a 4500 conexiones domiciliarias de las cuales el 90% tienen medidores activos y el 10% no tienen medidor. El consumo de agua facturado es del 63%, explicado por el consumo medido (91.37%) y consumo no medido (8.63%). Asimismo, el consumo de agua no facturado es del 37% explicado por el consumo autorizado no facturado (0.36%), las pérdidas comerciales (24.18%) y las pérdidas físicas (75.46%). Finalmente se estima que el ingreso de agua al sistema fue de 3732964 m3 de agua.es_PE
dc.description.abstractThe objective of this research was to determine the percentage of unbilled water of the potable water supply system of the city of Moyobamba, to identify the sources of potable water supply for the city of Moyobamba, to determine the water balance and the volume of water that entered the system of EPS Moyobamba, to determine the consumption of billed water and to determine the water losses in the potable water supply system of the city of Moyobamba. After data collection and processing, it was concluded that the water entering the system was approximately 3732964 m3, comprising the San Mateo subsystem, which supplies approximately 10,000 household connections, 90% of which have active meters and 10% do not have meters; Almendra, which supplies approximately 1000 household connections, 70% of which have active meters and 30% do not have meters, and Juninguillo, which supplies approximately 4500 household connections, 90% of which have active meters and 10% do not have meters. Billed water consumption amounts to 63%, explained by metered consumption (91.37%) and unmetered consumption (8.63%). Likewise, unbilled water consumption is 37%, explained by unbilled authorized consumption (0.36%), commercial losses (24.18%) and physical losses (75.46%). Finally, it is estimated that 3732964 m3 of water entered the system.es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Nacional de San Martín. Fondo Editoriales_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/deed.eses_PE
dc.sourceRepositorio - UNSMes_PE
dc.subjectAgua potablees_PE
dc.subjectAgua facturadaes_PE
dc.subjectAgua no facturadaes_PE
dc.titleAnálisis y determinación del agua no facturada por la EPS Moyobamba en el sistema de abastecimiento de agua potablees_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.disciplineIngeniería Sanitariaes_PE
thesis.degree.grantorUniversidad Nacional de San Martín. Facultad de Ecologíaes_PE
thesis.degree.nameIngeniero Sanitarioes_PE
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#1.06.13es_PE
renati.author.dni71880556-
renati.advisor.orcidhttps://orcid.org/0000-0003-3755-4093es_PE
renati.advisor.dni08008037-
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttps://purl.org/pe-repo/renati/nivel#tituloProfesionales_PE
renati.discipline733016es_PE
renati.jurorCenturion Tapia, Fabianes_PE
renati.jurorRojas Bardalez, Alfonsoes_PE
renati.jurorJulca Urquiza, Ronaldes_PE
item.grantfulltextopen-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.openairetypeinfo:eu-repo/semantics/bachelorThesis-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1es-
Appears in Collections:(Br.) Ingeniería Sanitaria
Files in This Item:
File Description SizeFormat 
ING. SANITARIA - Jhon Franklin Zamora Cercado.pdf1.88 MBAdobe PDFView/Open
Formato de Autorización.pdf377.89 kBAdobe PDFView/Open
REPORTE TURNITIN JHON FRANKLIN.pdf10.67 MBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons